home *** CD-ROM | disk | FTP | other *** search
Text File | 1994-01-01 | 74.8 KB | 2,425 lines |
-
-
-
-
-
-
-
-
-
- Ç ────────────────────────────────────────────
- Ç ┼┐════════════════════════════════════════════
- ╔╬╗ ┴
- ╨║╨ ┐
- ╔╩╗ ┴
- ╨ ╨
-
-
-
-
- ▒▒▒▒▒▒▒▄ ▒▒▒▒▒▒▒▒▄ ▒▒▄ ▒▒▄ ▒▒▄ ▒▒▄ ▒▒▄ ▒▒▄ ▒▒▄ ▒▒▄
- ▒▒█▀▀▀▒▒▄ ▒▒█▀▀▀▒▒█ ▒▒█ ▒▒█ ▒▒█ ▒▒▒▄ ▒▒▒█ ▒▒▒▒▄ ▒▒▒▄ ▒▒█
- ▒▒█ ▒▒█ ▒▒▒▒▒▒▒▒█ ▒▒█ ▒▒▄ ▒▒█▀ ▒▒▒▒▒▒▄ ▒▒▒█ ▒▒▒█ ▒▒█▀▒▒▄ ▒▒█▒▒▄▒▒█
- ▒▒█ ▒▒█ ▒▒█▀▀▒▒█▀ ▒▒█ ▒▒▒▒█▀ ▀▀▀▀▀▀ ▒▒█▒▒▄▒▒█ ▒▒▒▒▒▒█ ▒▒█ ▀▒▒▒█
- ▒▒▒▒▒▒▒█▀ ▒▒█ ▒▒█ ▒▒█ ▒▒█▀ ▒▒█▒▒█▒▒█ ▒▒█▀▀▀▒▒▄ ▒▒█ ▒▒█
- ▀▀▀▀▀▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀
-
-
- Welcome to DRIV_MAN, a utility program to assist
- you in your PC disk DRIVe MANagement!
-
-
-
-
-
-
-
-
-
-
- ▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀
-
- U S E R M A N U A L
-
- Version 1.2
-
- ▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄
-
- Copyright 1992-1994 by MicroMetric.
- All rights reserved.
-
- Document last edited: January 1, 1994
-
- DRIV_MAN is distributed as SHAREWARE and, as such, may be copied and shared on a
- private non-commercial basis with others in its unmodified form. Liability is
- limited to replacing the software for registered users. There is no liability
- for any damage or loss caused by this software, directly or indirectly.
- ┌────────────────────────────────────────────────┐
- │ ┌───────┐ │█
- │ ┌────┴──┐ │ (R) │█
- │ ──│ │O │─────────────────── │█
- │ │ ┌────┴╨─┐ │ Association of │█
- │ │ │ │─┘ Shareware │█
- │ └──│ O │ Professionals │█
- │ ─────│ ║ │───────────────────── │█
- │ └───╨───┘ MEMBER │█
- └────────────────────────────────────────────────┘█
- ██████████████████████████████████████████████████
-
- If you have problems with this program, or want to send comments, manual correc-
- tions, or enhancement suggestions, you may call or mail them to:
-
- MicroMetric
- 98 Dade Avenue
- Sarasota, FLorida 34232-1609 USA
-
- Technical Support (813) 377-2515
- FAX . . . . . . . (813) 377-2091
- Support BBS . . . (813) 371-2490
-
- The MicroMetric Software Support BBS provides availability and technical support
- for the MicroMetric ■■■■_MAN series of shareware programs. First time callers
- have access to the board and can leave messages or download replies/current
- shareware releases. Registered users may also download the latest Beta test
- software releases, when available.
-
- Additionally, you can send routed E-Mail via the RIME(tm) network to David
- Groome at the ->ACTION node in the ASP, Laser, Batch, Common, or Shareware con-
- ferences. I also check CompuServe (71631,744), but only on an infrequent basis.
-
- PKZIP, PKUNZIP and PKSFX are trademarks of PKWARE, Inc.
- MS-DOS is a registered trademark of the Microsoft Corporation.
- IBM PC, XT, AT and PC-DOS are registered trademarks of the IBM Corporation.
-
-
-
-
-
-
-
-
-
-
-
- ii
-
-
- TABLE OF CONTENTS
-
-
- INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
- Major Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
- System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 1
- Manual Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Page layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Brackets and parentheses . . . . . . . . . . . . . . . . . . . . . . 2
- Computer key conventions . . . . . . . . . . . . . . . . . . . . . . 2
- Action steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- ■■■■_MAN programs . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Shareware distributed documentation manual . . . . . . . . . . . . . 2
- Shareware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
-
- INSTALLING THE SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
- Installation on Non-Path Referenced Directories . . . . . . . . . . . . 5
- From a Diskette Vendor . . . . . . . . . . . . . . . . . . . . . . . . . 5
- From a BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
- Registered Version . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
- Program Operation with Microsoft Windows . . . . . . . . . . . . . . . . 11
-
- RUNNING DRIV_MAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
- Command Line Parameters . . . . . . . . . . . . . . . . . . . . . . . . 13
- Command Line FIRST-LAST DRIVE Examples . . . . . . . . . . . . . . . . . 13
-
- MAIN DISPLAY ACTION KEYS . . . . . . . . . . . . . . . . . . . . . . . . . 15
- Operation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
- Help Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
-
- MAIN DISPLAY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . 17
- General Display Information . . . . . . . . . . . . . . . . . . . . . . 18
- HEADER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
- DRIVE DATA GRAPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
- DRIVE DATA SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
- TOTAL DISK SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
- TOTAL DISK GRAPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
- INDIVIDUAL DRIVE DATA . . . . . . . . . . . . . . . . . . . . . . . . . 21
-
- EDITING THE DISK DRIVE RANGE . . . . . . . . . . . . . . . . . . . . . . . 23
-
- STORING THE DISPLAY DATA . . . . . . . . . . . . . . . . . . . . . . . . . 25
-
- RUNNING A FILE MANAGER . . . . . . . . . . . . . . . . . . . . . . . . . . 27
-
- EXTENDED FILE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . 29
-
- SHAREWARE REGISTRATION REMINDER SCREEN . . . . . . . . . . . . . . . . . . 31
-
- USING A CONFIGURATION FILE . . . . . . . . . . . . . . . . . . . . . . . . 33
-
- DRIV_MAN FILES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
-
- INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
-
- iii
-
- TABLE OF CONTENTS DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- iv
-
-
- INTRODUCTION
-
- DRIV_MAN is a disk utility management tool that displays pertinent logical disk
- drive data - up to twenty-six drives - on a SINGLE SCREEN for analysis/storage.
- It's great for use with multi-drive systems, networks, and large systems! The
- DRIV_MAN display includes: DRIVE DATA SUMMARY with capacity, used and free for
- each available/selected drive, DRIVE DATA GRAPH with the same data for each
- drive, TOTAL DISK SUMMARY and GRAPH, and INDIVIDUAL DRIVE DATA displaying full
- information on one drive at a time.
-
- Program options include: Toggle the sort order for the DRIVE DATA SUMMARY and
- GRAPH from six selections, selectable/editable display DRIVE RANGE, disk storage
- of the DISK DRIVE SUMMARY display, auto run, and the ability to run a file man-
- ager, FILE_MAN, from within the program.
-
- Major Features
-
- * SINGLE SCREEN data display of all selected/available disk drives.
- * Display SECTIONS include:
- - DRIVE DATA SUMMARY for all selected/available disk drives - A to Z - with
- capacity(Mb), used amount(Mb/Kb)/percent and free amount(Mb/Kb).
- - DRIVE DATA GRAPH with a column(Mb/Kb or %) for each drive depicting capac-
- ity, used and free.
- - TOTAL DISK SUMMARY(bytes) with capacity, used amount/percent, and free
- amount/percent.
- - TOTAL DISK GRAPH with used percent and free percent.
- - INDIVIDUAL DRIVE DATA(bytes) of capacity, used amount/percent, and free
- amount/percent. Drives may be scrolled through the full range of select-
- ed/available.
- * Display DRIVE DATA SUMMARY/GRAPH in any of six sorted orders.
- * Selectable disk DRIVE RANGE - command line or data entry menu.
- * Detects monitor type and sets colors accordingly.
- * Display colors are coordinated to highlight the various types of data.
- * Display data may be stored/appended to a disk file for archiving, later com-
- parison, etc.
- * May be run in automatic mode, such as in a batch file that runs as the first
- job of the day, to display and save the drive data.
- * FILE_MAN, a file manager shareware utility, may be run directly from
- DRIV_MAN.
- * Display additional allocation information for each drive.
- * Context sensitive help is available for all actions.
- * Registered users may suppress the shareware registration reminder message
- displays and receive a printed/bound manual along with the ability set/change
- the display colors and position the various display sections using a configu-
- ration file..
-
- System Requirements
-
- IBM PC, XT, AT or true compatibles operating with PC/MS-DOS, version 3.0 or
- later. It supports both NETBIOS networks and "huge" hard disk drives formatted
- for more than 32MB. The program will determine what type of display monitor is
- available and adjust itself accordingly.
-
-
-
- 1
-
- INTRODUCTION DRIV_MAN Version 1.2
-
- Manual Format
-
- This manual is divided into several introductory chapters followed by chapters
- for operating DRIV_MAN. The format of these chapters and the information pre-
- sented therein has been standardized using the following conventions.
-
- Page layout - Each page has a header detailing the chapter and the program ver-
- sion covered. A footer displays the manual page number.
-
- Brackets and parentheses - Brackets, [...], are used in the manual and in the
- help screens to specify what should be entered in response to the current
- prompt. If a character string is to be entered, the type of character is noted,
- such as ALPHA, NUMERIC, ANY, etc. Parentheses, (..), are used for comments.
-
- Computer key conventions - Keys specified in the manual text that are not in
- entry brackets are shown as reversed, such as ESCAPE . All key references are
- in capital letters for clarity.
-
- Action steps - Some procedures may require selection from a menu of options,
- inputting data or following a sequence of steps. Most manual sections will first
- give an overview of the function or task under discussion and then detail the
- various action operating procedures. In order to make this manual easier to use
- a symbol, -> , marks the beginning of each of these action operating procedures.
-
- ■■■■_MAN programs - The general group of shareware programs by MicroMetric is
- referred to by the name ■■■■_MAN. It may also be used in reference to a specific
- program in that group.
-
- Shareware distributed documentation manual - The documentation file included on
- the shareware distribution diskette contains the same information as the printed
- and bound manual, supplied as part of registration, with two exceptions, the
- result of the word processor, formatting, and printer used. The first is that
- all of the control display characters (ASCII 1-31) and the reverse print key-
- board codes are NOT shown properly. Finally, bolding, underlining, and special
- symbols are NOT present.
-
- Shareware
-
- DRIV_MAN is being distributed as SHAREWARE. The SHAREWARE concept allows users
- to examine a program on a trial basis, at no (or minimal) charge, before pur-
- chasing it. In addition, by decreasing marketing costs, professional quality
- software may be distributed for a fraction of the cost of a comparable commer-
- cial product. Regardless of whether you register the program, please help dis-
- tribute DRIV_MAN by sharing unmodified copies of it and its files with others.
-
- You are hereby granted the right to use the DRIV_MAN program for a thirty (30)
- day evaluation period. If you find DRIV_MAN of value, and continue to use it
- after this evaluation period, YOU MUST REGISTER YOUR PROGRAM USE. This will
- provide you with:
-
-
-
-
-
- 2
-
- DRIV_MAN Version 1.2 INTRODUCTION
-
- * A 7" x 8 1/2" printed and bound manual.
- * DRIV_MAN phone or mail support for one year.
- * Notification of the next DRIV_MAN release.
- * Ability to suppress the shareware registration reminder message displayed
- at the end of the program.
- * Ability to use a configuration file to specify the display colors and
- position of data areas along with other program setup parameters.
- * An installation/update/registration branding program.
- * Sincere thanks for your support of the SHAREWARE concept.
-
- A Single System Program Registration entitles the user to unlimited use of the
- DRIV_MAN program on a single computer.
-
- A Site License Program Registration entitles the user to unlimited use of the
- DRIV_MAN program on all computers, including networks, at a single corporate
- location.
-
- Program Registration, Single System . . . . . $20.
- Includes latest version diskette and manual
- Program Registration, Site License . . . . $100.
- Includes latest version diskette and manual
- Latest Version Diskette only . . . . . . . . $10.
- Shipping - USA/Canada/Mexico . . . . . . . . $5.
- Shipping - Air (for outside of USA/Canada/Mexico only)$10.
- COD orders, add $5.
- Florida residents, add 7% sales tax.
-
- You should specify diskette size and density desired. If none is specified, 3½"
- DSHD will normally be supplied.
-
- ADDRESS: MicroMetric
- 98 Dade Avenue
- Sarasota, FLorida 34232-1609 USA
-
- PHONE: Technical Support (813) 377-2515
- FAX . . . . . . . (813) 377-2091
- Support BBS . . . (813) 371-2490
- Order Line . . . (800) 929-0184
-
- For ease in program registration, a registration order form may be printed at
- the program exit or there is a quick registration form that is available with
- the program F1 help key.
-
- This program is produced by a member of the Association of Shareware Profession-
- als (ASP). ASP wants to make sure that the shareware principal works for you. If
- you are unable to resolve a shareware-related problem with an ASP member by
- contacting the member directly, ASP may be able to help. The ASP Ombudsman can
- help you resolve a dispute or problem with an ASP member, but does not provide
- technical support for members' products. Please write to the ASP Ombudsman at
- 545 Grover Road, Muskegon, MI 49442-9427, send a CompuServe message via easyplex
- to ASP Ombudsman 70007,3536, or by FAX to the ASP FAX number: (616) 788-2765. In
- communications with the Ombudsman please include a telephone number and/or FAX
- if available.
-
- 3
-
- INTRODUCTION DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 4
-
-
- INSTALLING THE SYSTEM
-
- Installation on Non-Path Referenced Directories
-
- If the DRIV_MAN files are not located on PATH referenced directories, then, when
- executing DRIV_MAN, either:
-
- 1. The drive-directory on which they are located must be made the current
- one, or
- 2. The drive-directory on which they are located must be specified on the
- command line.
-
- See the chapter "Running DRIV_MAN" for more complete details on operation if the
- files are not located on path directories.
-
- From a Diskette Vendor
-
- If the DRIV_MAN program has been obtained from a diskette vendor, you should
- follow any of their instruction on unpacking/installing the programs (if indeed
- they have separate instructions.) The program, and its files, can be supplied as
- a self extracting file whose name is "DMANvvv.EXE" (vvv is the version, such as
- "DMAN100").
-
- This file should first be copied to a directory on your hard disk. This direc-
- tory may be a new one, such as one named "DRIV", and created specifically for
- DRIV_MAN, or a current one, such as "UTILITY", that has other programs/files.
- For information on creating a separate directory, see your DOS manual.
-
- Once the file is copied to the desired hard disk directory, at the DOS prompt
- change to this drive directory, and then type the EXE file name (such as
- "DMAN100") and press ENTER . This will unpack all of the DRIV_MAN files.
-
- From a BBS
-
- If the DRIV_MAN file was downloaded from a Bulletin Board, it should first be
- copied to a directory as defined above, and then unpacked, using whatever pro-
- gram is specified by the Bulletin Board. It is normally distributed with a name
- of "DMANvvv.ZIP" (vvv is the version) or "DMANvv.ZIP" and requires the program
- PKUNZIP, version 2, to unpack the files.
-
- Registered Version
-
- Registered users should use the program "INSTALL", that is supplied upon regis-
- tration. This program will create a registration file which will, in turn, sup-
- press the shareware registration reminders. If the system is already installed,
- and only "BRANDING" the system with the registration information is desired, you
- can run the program "DRIV_MAN", and when exiting, select the "BRAND" option by
- pressing F4 .
-
- -> To install DRIV_MAN on your hard disk, or to upgrade to a new release, follow
- the steps detailed below:
-
- 1. Place the DRIV_MAN distribution diskette in your floppy diskette drive.
-
-
- 5
-
- INSTALLING THE SYSTEM DRIV_MAN Version 1.2
-
- 2. At the DOS prompt, change to the drive in which the distribution diskette is
- located. For example, if the diskette was placed in drive A, type A : and
- press ENTER .
-
- 3. Type I N S T A L L and press ENTER . The installation program
- will then be loaded, and its display should be as shown below.
- ╒═╡ INSTallation MANagement Program ╞══════════╡ Started at═>12-31-99 08:00 ╞═╕
- │░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░│
- │░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░│
- │░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░│
- │░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░│
- │░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░│
- │░ ░░▄ ░░▄ ░░▄░░░░░░░░▄░░░░░░░░▄ ░░▄ ░░▄ ░░▄ ░░▄ ░░▄░│
- │░ Ç ░░█ ░░░▄ ░░█░░█▀▀▀▀▀▀ ▀▀░░█▀▀▀ ░░░▄ ░░░█ ░░░░▄ ░░░▄ ░░█░│
- │░ ┌┼┐ ░░█ ░░█░░▄░░█░░░░░░░░▄ ░░█ ░░░█ ░░░█ ░░█▀░░▄ ░░█░░▄░░█░│
- │░ ┌┴┐ ░░█ ░░█ ▀░░░█ ▀▀▀▀▀░░█ ░░█ ░░█░░▄░░█ ░░░░░░█ ░░█ ▀░░░█░│
- │░═┴═┴═░░█ ░░█ ░░█░░░░░░░░█ ░░█ ░░░░░░▄ ░░█░░█░░█░░█▀▀▀░░▄░░█ ░░█░│
- │░ ▀▀ ▀▀ ▀▀ ▀▀▀▀▀▀▀▀ ▀▀ ▀▀▀▀▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀ ▀▀░│
- ╘╡ INST_MAN Version 4.20 Copyright 1990-94 MicroMetric, All Rights Reserved ╞╛
- F1>Help│ESC>Exit│<┘/[char]>Select│ HomeEnd│
-
- NOTE Context sensitive help is available from this point on in the in-
- stallation program on, by pressing the F1 key. For more informa-
- tion on the help available, see the "Help Key" section in the "Run-
- ning DRIV_MAN" chapter.
-
- 4. If a color video card is detected, the following prompt will be displayed.
- ┌──────────────────────────────────────┐
- │ ╔═╡ Color Monitor Card Detected ╞═╗ │
- │ ║ Use the color display ║█ │
- │ ║ Force a monochrome display ║█ │
- │ ╚═════════════════════════════════╝█ │
- │ ███████████████████████████████████ │
- └──────────────────────────────────────┘
- -> If your system has a color monitor, press U .
- -> If your system has a monochrome or LCD display, press F .
-
- 5. A selection list of all path referenced directories is next displayed.
-
- NOTE Although DRIV_MAN will run from a non-path directory, placing its
- files on any path-referenced directory(s) allows the directory from
- which files are to be printed to be set as the current directory,
- before executing the program.
-
-
-
-
-
-
-
-
-
-
-
- 6
-
- DRIV_MAN Version 1.2 INSTALLING THE SYSTEM
-
- ┌────────────────────────────────────────────┐
- │ ┌─┤ Select the INSTALLATION DIRECTORY ├─┐ │
- │ │ C:\BAT │█ │
- │ │ C:\DOS-500 │█ │
- │ │ C:\UTILITY │█ │
- │ │ C:\ZIP │█ │
- │ │ C:\ │█ │
- │ │ User Defined Drive-Directory Path │█ │
- │ └───────────────────────────────────────┘█ │
- │ █████████████████████████████████████████ │
- └────────────────────────────────────────────┘
- -> To cancel the installation program at this point, press ESCAPE .
- -> To select one of the path referenced directories on which to install
- DRIV_MAN, move the highlight bar to it and press ENTER .
- -> To specify a non-path referenced directory on which to install DRIV_MAN,
- press U and then press ENTER . A data entry window for the installation
- path will then be displayed, as shown below (with an example path already
- entered). Enter the desired drive and directory path on which to install
- DRIV_MAN, using the control keys described on the bottom help line.
-
- NOTE INSTALL can only create directories one level deeper than that
- which currently exists. If the directory C:\ABC exists, the di-
- rectory C:\ABC\XYZ may be created; if C:\ABC does not already
- exist, an error will occur.
- ┌────────────────────────────────────────────────────────────────────────┐
- │ ┌─┤ Enter Path ├────────────────────────────────────────────────────┐ │
- │ │ C:\DRIV │█ │
- │ └───────────────────────────────────────────────────────────────────┘█ │
- │ █████████████████████████████████████████████████████████████████████ │
- └────────────────────────────────────────────────────────────────────────┘
- -> To cancel defining the path, press ESCAPE . The program will return to
- directory selection.
- -> To accept the path as entered and edited, press ENTER . If the speci-
- fied directory does not currently exist, the following message will be
- displayed.
- ┌────────────────────────────────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├───────────────────────────────────────────────────┐ │
- │ │ The drive-directory path as entered DOES NOT currently exist. │█ │
- │ │ This directory WILL NOW BE created. │█ │
- │ └───────────────────────────────────────────────────────────────┘█ │
- │ █████████████████████████████████████████████████████████████████ │
- └────────────────────────────────────────────────────────────────────┘
- -> To cancel creation of this directory, press ESCAPE .
- -> To create it, press ENTER . If the specified drive is invalid or
- the requested installation directory's parent does not exist, an
- error message will be displayed.
-
-
-
-
-
-
-
-
- 7
-
- INSTALLING THE SYSTEM DRIV_MAN Version 1.2
-
- ┌─────────────────────────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├────────────────────────────────────────────┐ │
- │ │ The drive-directory path as entered CANNOT BE CREATED. │█ │
- │ │ Please edit and CORRECT this path. │█ │
- │ └────────────────────────────────────────────────────────┘█ │
- │ ██████████████████████████████████████████████████████████ │
- └─────────────────────────────────────────────────────────────┘
- Press any key, and then re-edit the installation path.
-
- 6. A TYPE OF INSTALLATION selection menu will next be displayed. INSTALL will
- process either ■■■■_MAN SYSTEMS or their SUPPLEMENTAL FILES.
-
- SYSTEMS consist of the files necessary for basic program operation.
-
- SUPPLEMENTAL FILES contain additional information needed to accomplish added
- support or increased functionality.
- ┌───────────────────────────────┐
- │ ╔═╡ TYPE OF INSTALLATION ╞═╗ │
- │ ║ Systems - Programs ║█ │
- │ ║ supplemental Files ║█ │
- │ ║ eXit Installation ║█ │
- │ ╚══════════════════════════╝█ │
- │ ████████████████████████████ │
- └───────────────────────────────┘
- -> To install one or more SYSTEMS at this time, press S . A menu of avail-
- able SYSTEMS will then be displayed. For further installation instruc-
- tions, go to the next step.
-
- NOTE THIS APPLICATION CURRENTLY DOES NOT HAVE SUPPLEMENTAL FILES.
-
- -> To exit the INSTALL program at this time, press X .
-
- 7. If more than one system is available for installation, a SYSTEM TO INSTALL
- selection menu will be displayed, as shown below.
- ┌─────────────────────────────────────────────────────────────────────────────┐
- │ ╔═╡ TAG ╞╡ Select the SYSTEM(S) TO INSTALL ╞═════════════════════════════╗ │
- │ ║ DMAN100 SINGLE SCREEN data/graphical summary all disk drives ║█ │
- │ ║ EMAN100 Environment data summary, environ. space remaining ║█ │
- │ ║ FMAN100 Menu driven DOS file manager, directory tree ║█ │
- │ ║ LMAN100 Print text files on a laser printer, 36 print styles ║█ │
- │ ║ MMAN100 Display custom user selection menus from batch files ║█ │
- │ ║ PMAN100 Determines if a file is on a PATH directory ║█ │
- │ ║ VMAN100 Display and edit files in both ASCII and Hex ║█ │
- │ ║ ------ eXIT SELECTION AND INSTALL ALL TAGGED (√) ------ ║█ │
- │ ╚════════════════════════════════════════════════════════════════════════╝█ │
- │ ██████████████████████████████████████████████████████████████████████████ │
- └─────────────────────────────────────────────────────────────────────────────┘
- -> To terminate the installation program at this point, press ESCAPE .
- -> To toggle the INSTALL TAG for a given SYSTEM, press its highlighted letter
- or move the highlight bar to in with the arrow keys and press ENTER . A
- [√] character to the left of the SYSTEM name denotes that this SYSTEM will
- be installed.
- -> To conclude the SYSTEM selection process, press X . The INSTALLATION
-
- 8
-
- DRIV_MAN Version 1.2 INSTALLING THE SYSTEM
-
- FUNCTION menu for each selected system will then be displayed.
-
- 8. A list of all of the selected SYSTEMS files is next displayed, along with an
- INSTALLATION FUNCTION menu. The normal sequence of operations is to first
- "Install" the SYSTEM program and files, and then "Brand" the SYSTEM with your
- name and serial number.
- ┌─────────────────────────────────────────────────────────────┐
- │ ╒═╡ Select the INSTALLATION FUNCTION ╞═══════════════════╕ │
- │ │ Install system Brand system eXit │█ │
- │ ╘════════════════════════════════════════════════════════╛█ │
- │ ██████████████████████████████████████████████████████████ │
- └─────────────────────────────────────────────────────────────┘
-
- ┌──────────────────────────────────────────────────────────────────────────────┐
- │╒═╡ File Name Status Hard Disk Path/File Description XXXX100 FILES ╞═╕ │
- ││ System═>XXXX_MAN This system does .................. │█│
- ││ XXXX_MAN.EXE PROCESS Main program for this application │█│
- ││ YYYY.YYY PROCESS Other files... │█│
- │╘═╡ INSTALLATION PATH═>C:\DRIV ╞════════════════════════════════════════════╛█│
- │ █████████████████████████████████████████████████████████████████████████████│
- └──────────────────────────────────────────────────────────────────────────────┘
-
- -> To install the SYSTEM on the hard disk, insure that the highlight bar is
- on the "INSTALL SYSTEM" FUNCTION and press ENTER . Each of the file(s)
- will be copied to the selected installation drive-directory.
-
- NOTE A happy face symbol after any of the SYSTEM's file names denotes
- that this file is already on the hard disk. During installation
- it will be replaced, on the directory where it currently resides,
- not the INSTALLATION DRIVE-DIRECTORY PATH.
-
- If any of the files to be installed is already present, a ACTION menu will
- be displayed during its installation.
- ┌───────────────────────────────────────────────────────┐
- │ ┌─┤ Highlighted file(s) already present. ACTION? ├─┐ │
- │ │ Erase current file(s) and update │█ │
- │ │ erase and update this and All later file(s) │█ │
- │ │ Leave current file(s) 'as is' │█ │
- │ │ leave current and Skip the remaining file(s) │█ │
- │ └──────────────────────────────────────────────────┘█ │
- │ ████████████████████████████████████████████████████ │
- └───────────────────────────────────────────────────────┘
- -> To process the current file, select the proper ACTION to take by press-
- ing its highlighted letter or moving the highlight bar to it and press-
- ing ENTER .
-
- When all files have been copied to the hard disk, a copy complete message
- is displayed.
-
-
-
-
-
-
- 9
-
- INSTALLING THE SYSTEM DRIV_MAN Version 1.2
-
- ┌───────────────────────────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├──────────────────────────────────────────────┐ │
- │ │ FILE COPY COMPLETED. │█ │
- │ │ All of the required DRIV_MAN files are on the hard disk. │█ │
- │ │ ═══> DRIV_MAN IS READY TO RUN. <═══ │█ │
- │ └──────────────────────────────────────────────────────────┘█ │
- │ ████████████████████████████████████████████████████████████ │
- └───────────────────────────────────────────────────────────────┘
- -> To cancel the installation at this point, press ESCAPE .
- -> To continue with the installation, press any other key. The highlight
- bar will then be on the "BRAND SYSTEM" FUNCTION.
-
- 9. To brand the system with your name and serial number, move the highlight bar
- to the "BRAND SYSTEM" FUNCTION and press ENTER . A REGISTRATION INFORMATION
- data entry window will be displayed, as shown below, with sample data already
- entered.
-
- NOTE This step is REQUIRED for DRIV_MAN to be registered. Also, if you
- move the DRIV_MAN files to another drive-directory you will need to
- "BRAND" the system again.
-
- Enter your company and/or your name, and then the system registration
- number. Your registration number is located on the back of the front cover
- of this manual.
- ┌──────────────────────────────────────────┐
- │ ┌─┤ REGISTRATION INFORMATION ├────────┐ │
- │ │ Name ABC COMPANY, George Jones │█ │
- │ │ Registration number 12345678 │█ │
- │ └─────────────────────────────────────┘█ │
- │ ███████████████████████████████████████ │
- └──────────────────────────────────────────┘
- -> To accept either the name or registration number after entry and edit-
- ing, press ENTER . A message will be displayed after the registration
- number is entered. It's contents are dependent on whether the registra-
- tion number is valid. Both messages are shown below.
- ┌───────────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├──────────────────────────────┐ │
- │ │ DRIV_MAN serial number entered is VALID. │█ │
- │ └──────────────────────────────────────────┘█ │
- │ ████████████████████████████████████████████ │
- └───────────────────────────────────────────────┘
-
- ┌─────────────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├────────────────────────────────┐ │
- │ │ DRIV_MAN serial number entered is INVALID! │█ │
- │ │ Please try again. │█ │
- │ └────────────────────────────────────────────┘█ │
- │ ██████████████████████████████████████████████ │
- └─────────────────────────────────────────────────┘
- -> To continue with the installation program, press any key. If the
- registration number was valid, the "EXIT" option is highlighted. If
- it was invalid, select the "BRAND SYSTEM" option again.
-
-
- 10
-
- DRIV_MAN Version 1.2 INSTALLING THE SYSTEM
-
- 10. To exit from this SYSTEMS installation function, move the highlight bar to
- the "EXIT" FUNCTION and press ENTER . If the SYSTEM has been properly
- branded, it is ready for use, and the program will either install the next
- selected SYSTEM, Step 8, or return to the TYPE OF INSTALLATION MENU, Step
- 6. If the system has not been branded, an error message is displayed, as
- shown below.
- ┌─────────────────────────────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├────────────────────────────────────────────────┐ │
- │ │ This system has not been 'BRANDED'. │█ │
- │ │ In order to be registered, it must first be 'BRANDED'! │█ │
- │ │ To exit without BRANDING, press ESCAPE. │█ │
- │ │ To continue with the INSTALL program, press any other key. │█ │
- │ └────────────────────────────────────────────────────────────┘█ │
- │ ██████████████████████████████████████████████████████████████ │
- └─────────────────────────────────────────────────────────────────┘
-
- Program Operation with Microsoft Windows
-
- DRIV_MAN may be run as a DOS application under Windows. To aid in its operation,
- an icon file, "DRIV_MAN.ICO", and a program information file, "DRIV_MAN.PIF",
- have been included. These should be installed into a Windows program group. See
- your Microsoft Windows manual for specific installation details.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 11
-
- INSTALLING THE SYSTEM DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 12
-
-
- RUNNING DRIV_MAN
-
- Command Line Parameters
-
- The syntax for running DRIV_MAN is:
-
- [drive:path]DRIV_MAN [[first_drive][-][last_drive]][/a][/c][/gxxx][/m]
-
- where:
- first_drive default = C
- last_drive default = LASTDRIVE as defined in DOS
- CONFIG.SYS
-
- /a = Automatic execution of DRIV_MAN and storage of the display. This
- method is designed for use in batch files, such as a batch file that
- runs once a day.
- /c = Force CGA monitor.
- /gxxx = Optional configuration file extension (default is CFG). USE OF
- THE CONFIGURATION FILE IS LIMITED TO REGISTERED USERS ONLY.
- Example: /gcg2 will use "DRIV_MAN.CG2".
- /m = Force monochrome monitor.
-
- NOTE Command line parameters may be in either lower or UPPER case.
- Spaces between the program name and each of the parameter(s) are
- optional.
-
- Command Line FIRST-LAST DRIVE Examples
-
- SYNTAX DRIVES DISPLAYED
- ════════════ ═════════════════
-
- DRIV_MAN C D . . LASTDRIVE
- DRIV_MAN D D
- DRIV_MAN D- D E . . LASTDRIVE
- DRIV_MAN - C D . . LASTDRIVE
- DRIV_MAN D-F D E F
- DRIV_MAN B-F B C D E F
- DRIV_MAN C-C C
- DRIV_MAN -E C D E
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 13
-
- RUNNING DRIV_MAN DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 14
-
-
- MAIN DISPLAY ACTION KEYS
-
- Operation Keys
-
- These keys are active when DRIV_MAN is waiting for input at the main display.
-
- F1 . . . Display the Help Information. (See the HELP Key section below)
- F2 . . . Change the range of the displayed drives.
- F3 . . . Store the current at the end of the file DRIV_MAN.DAT.
- F4 . . . Shell out to the specified file manager.
- F10 . . . Re-read each drive's data and display additional information.
-
- ENTER ESC Exit the program.
-
- RIGHTARROW LEFTARROW Sort the DRIVE DATA SUMMARY/GRAPH information. The
- order that will be toggled through is:
-
- Drive Letter
- Capacity
- Utilization
- % Utilization
- Free
- % Free (reverse of % Utilization)
-
- char HOME END UPARROW DOWNARROW PAGEUP PAGEDOWN Change the INDI-
- VIDUAL DRIVE DATA display.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 15
-
- MAIN DISPLAY ACTION KEYS DRIV_MAN Version 1.2
-
- Help Key
-
- Pressing the help key, F1 , displays a context sensitive help page window such
- as shown below. The help page shown below is the first one available as shown by
- the page number 0 in the upper right corner. Page 0 acts as a help page menu for
- this program. The help page actually displayed when the help key is pressed
- depends on the actions of the program and will be the most appropriate for the
- program at that point. The bar shown on the right edge of the help window de-
- picts the position of this screen with regard to the total text of the current
- help page.
- ┌──────────────────────────────────────────────────────────────────────────────┐
- │╒═╡ Help Page 0 ═> HELP INDEX ╞═╕ │
- ││ SECTION HELP PAGE ^█│
- ││ ───────────────────────────────────────────────────────────────────────── ▒█│
- ││ INTRODUCTION........................................................ 1 ▒█│
- ││ COMMAND LINE PARAMETERS............................................. 2 ▒█│
- ││ ACTION KEYS and DISPLAY INFORMATION................................. 3 ▒█│
- ││ [F2] EDITING THE DISK DRIVE RANGE................................... 4 ▒█│
- ││ [F3] STORING THE DATA............................................... 5 ▒█│
- ││ [F4] RUNNING THE FILE MANAGER....................................... 6 ▒█│
- ││ [F10] EXTENDED FILE INFORMATION..................................... 6 ▒█│
- ││ CONFIGURATION FILE.................................................. 7 ▒█│
- ││ SHAREWARE REGISTRATION, SUPPORT INFORMATION......................... 8 ▒█│
- ││ ▒█│
- ││ In this Help Module, the use of brackets [ ] denotes a specific key. ▒█│
- ││ ▒█│
- ││ Parenthesis ( ) are used for comments. ▒█│
- ││ ▒█│
- ││ The bottom line of the display is used for help key information, showing ▒█│
- ││ the currently active help action keys and their function. v█│
- │╘═══════════════════════════════════════════════════════════════════════════╛█│
- │ █████████████████████████████████████████████████████████████████████████████│
- │ <┘/ESC>ExitHelp│[F1]>HelpIndex│[1 9 A Z]>HelpPage│Pageup Pagedown Home End │
- └──────────────────────────────────────────────────────────────────────────────┘
-
- -> To display context sensitive help information while the program is waiting
- for a response to a prompt, press F1 . The help window control keys are
- covered below.
-
- F1 0 . . Display Help Page Index Menu, Page 0
- ESC ENTER Remove Help Window & return to the program
- HOME . . . Display first screen of the current Help Page
- END . . . . Display last screen of the current Help Page
- PAGE UP . . Display previous screen of the current Help Page
- PAGE DOWN . Display next screen of the current Help Page
- 1-9 A-Z . Display the corresponding Help Page
-
-
-
-
-
-
-
-
- 16
-
-
- MAIN DISPLAY INFORMATION
-
- The DRIV_MAN display has been designed to present the maximum amount information
- on all of the disk drives on a system - up to twenty-six - on a single screen.
-
- The example shown below is from a network with three servers:
-
- SERVER 1 has logical drives C-L with Ram drive M,
- SERVER 2 has logical drives O-X and
- SERVER 3 has logical drives Y and Z.
-
- ╒═╡ DRIVe_MANagement Disk (C-Z) Summary ╞══════════════════╡ 12/31/99 01:00 ╞═╕
- │ 130▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒Z░░D Cap Utilized Free│D Cap Utilized Free│
- │ 123░░░░░░░░░░░░░░░░░░░░░░░░░│░░R Mb Mb/Kb % Mb/Kb│R Mb Mb/Kb % Mb/Kb│
- │ 116▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│░░░░░░░░░░░░░░░░░░░░░░░░│░░░░░░░░░░░░░░░░░░░░░░│
- │ 109░░░░░░░░░░░░░░░░░░░░░░░░░│░░░░░░░░░░░░░░░░░░░░░░░░│O__35__32.1m_92___2.9m│
- │ 102▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│░░C 33 16.2m 48 17.2m│P__70__60.7m_87___9.2m│
- │ 95░░░░░░░░░░░░░░░░░░░░░░░░░│░░D 67 42.3m 63 24.5m│Q__70__43.8m_63__26.1m│
- │ 88▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│░░E 67 28.1m 42 38.8m│R__70__33.4m_48__36.5m│
- │ 82░░░░░░░░░░░░░░░░░░░░░░░░░│░░F 67 37.1m 55 29.7m│S__70__56.3m_81__13.6m│
- │ 75▒▒▒▒▒▒▒▒▒▒K▒▒▒▒▒▒▒▒▒▒▒▒▒▒│░░G 67 26.7m 40 40.1m│T__70__48.4m_69__21.5m│
- │ 68░░░░░░░░░░│░░░░PQRSTUV░░░│░░H 67 52.7m 79 14.1m│U__70__33.3m_48__36.6m│
- │ 61▓▓▓DEFGHIJ│▓▓▓▓│││││││▓▓▓│░░I 67 39.5m 59 27.3m│V__70__32.8m_47__37.1m│
- │ 54░░░││││││║│░░░░║││║│││░░░│░░J 67 57.2m 86 9.6m│W__35__34.0m_97_970.8k│
- │ 47▒▒▒││││║│║│▒▒▒▒║││║║││▒▒▒║░░K 80 38.6m 48 41.6m│X__11___7.2m_64___4.1m│
- │ 41░░░║│││║│║│░░░░║║│║║││░░░║░░L 19 12.2m 64 6.8m│Y__15__10.8m_73___3.9m│
- │ 34▒▒▒║│║│║║║║▒▒▒O║║│║║││W▒▒║░░M...1...0.0k..0.520.2k│Z_130__51.3m_39__79.1m│
- │ 27░░C║║║│║║║║░░░║║║║║║║║║░░║░░┌Total Bytes CAPACITY = 1,316,579,328───────┐│
- │ 20▒▒│║║║║║║║║▒▒▒║║║║║║║║║▒▒║░░│Total Bytes UTILIZED = 794,632,192 (60%) ││
- │ 13░░║║║║║║║║║L░░║║║║║║║║║░Y║░░└────Total Bytes FREE = 521,947,136 (40%)───┘│
- │ 6▒▒║║║║║║║║║║▒▒║║║║║║║║║X║║░░┌0% 10 20 30 40 50 60 70 80 90 100┐│
- │Mb 0░░CDEFGHIJKLM░OPQRSTUVWXYZ░░└▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀┘│
- │░░╒╡ DRIVE C ╞═════╡ CAPACITY ╞═════╡ UTILIZED ( 48.4%) ╞╡ FREE ( 51.6%) ╞╕░░│
- │░░╘╡ UTILITY-4C ╞╡ 33,431,552 ╞╡ 16,183,296 ╞════╡ 17,248,256 ╞╛░░│
- ╘╡ DRIV_MAN Version 1.20, Copyright 1992-94 MicroMetric, All Rights Reserved ╞╛
- F1>Help│F2>Range│F3>Store│F4>FILE_MAN│<┘/ESC>Exit│ >Sort(DR)│[char] >Drive│
-
- -> To exit from the program, press ESCAPE or ENTER .
-
- -> To execute any of the DRIV_MAN functions shown on the bottom help line, press
- the desired key. These functions are described in detail in the following
- chapters.
-
-
-
-
-
-
-
-
-
-
-
-
-
- 17
-
- MAIN DISPLAY INFORMATION DRIV_MAN Version 1.2
-
- General Display Information
-
- The DRIV_MAN SINGLE SCREEN display is divided into several SECTIONS - DRIVE DATA
- GRAPH, DRIVE DATA SUMMARY, TOTAL DISK SUMMARY, TOTAL DISK GRAPH, and INDIVIDUAL
- DRIVE DATA - as depicted in this diagram.
- ╔═══════════════════════════════╗
- ║<──────────HEADER─────────────>║
- ║┌DRIVE DATA┐┌DRIVE DATA───────┐║
- ║│░░░░░░░░░░││▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓│║
- ║│░░░░░░░░░░││▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓│║
- ║│░░░░░░░░░░│└──────────SUMMARY┘║
- ║│░░░░░░░░░░│┌TOTAL DISK───────┐║
- ║│░░░░░░░░░░│└──────────SUMMARY┘║
- ║│░░░░░░░░░░│┌TOTAL DISK───────┐║
- ║└─────GRAPH┘└────────────GRAPH┘║
- ║┌INDIVIDUAL───────────────────┐║
- ║│▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│║
- ║└───────────────────DRIVE DATA┘║
- ║<──program/registration info──>║
- ║<─────────help line───────────>║
- ╚═══════════ SCREEN ════════════╝
-
- Data for each logical drive is shown, if: 1.) It is included in the selected
- drive range, and 2.) it exists.
-
- Color is used extensively in the display to differentiate the different data
- types, such as Drives, Capacity, Utilization, and Free.
-
- The display, color, and position of each SECTION can be controlled by registered
- users with the use of the optional configuration file. For detailed information
- on this feature, see the chapter "Using the Configuration File".
-
- HEADER
- ┌─────────────────────────────────────────────────────────────────────────────┐
- │ ╡ DRIVe_MANagement Disk (C-Z) Summary ╞══════════════════╡ 12/31/99 01:00 ╞ │
- └─────────────────────────────────────────────────────────────────────────────┘
-
- The left portion of the header line denotes the first and last logical disk
- drives included in the display summary. These drives may range between A and Z.
- Unless they are initially specified on the command line they will be
- C-LASTDRIVE, as defined by DOS. This range may be changed by pressing F2 .
-
- The date and time displayed are that when disk data was last obtained, in 24
- hour notation, are shown in the right portion of the header.
-
-
-
-
-
-
-
-
-
-
- 18
-
- DRIV_MAN Version 1.2 MAIN DISPLAY INFORMATION
-
- DRIVE DATA GRAPH
- ┌────────────────────────────────┐
- │ 130▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒Z │
- │ 123░░░░░░░░░░░░░░░░░░░░░░░░░│ │
- │ 116▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │
- │ 109░░░░░░░░░░░░░░░░░░░░░░░░░│ │
- │ 102▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │
- │ 95░░░░░░░░░░░░░░░░░░░░░░░░░│ │
- │ 88▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │
- │ 82░░░░░░░░░░░░░░░░░░░░░░░░░│ │
- │ 75▒▒▒▒▒▒▒▒▒▒K▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │
- │ 68░░░░░░░░░░│░░░░PQRSTUV░░░│ │
- │ 61▓▓▓DEFGHIJ│▓▓▓▓│││││││▓▓▓│ │
- │ 54░░░││││││║│░░░░║││║│││░░░│ │
- │ 47▒▒▒││││║│║│▒▒▒▒║││║║││▒▒▒║ │
- │ 41░░░║│││║│║│░░░░║║│║║││░░░║ │
- │ 34▒▒▒║│║│║║║║▒▒▒O║║│║║││W▒▒║ │
- │ 27░░C║║║│║║║║░░░║║║║║║║║║░░║ │
- │ 20▒▒│║║║║║║║║▒▒▒║║║║║║║║║▒▒║ │
- │ 13░░║║║║║║║║║L░░║║║║║║║║║░Y║ │
- │ 6▒▒║║║║║║║║║║▒▒║║║║║║║║║X║║ │
- │ Mb 0░░CDEFGHIJKLM░OPQRSTUVWXYZ │
- └────────────────────────────────┘
-
- The DRIVE DATA GRAPH is scaled to the largest logical drive selected/available.
- Each logical drive's data is displayed in a single column, from A-Z.
-
- The drive's CAPACITY is denoted by the display of two drive letters. The lower
- bar depicts the portion of the drive currently utilized and the upper bar is for
- that amount which is free. On color monitors, the utilized and free bars are
- displayed in different colors.
-
- The example above shows Drive C has a CAPACITY between 27 and 34 Megabytes(Mb)
- and a UTILIZATION between 13 and 20 Mb. Drive M has both figures - CAPACITY and
- UTILIZATION - between 0 and 6 Mb.
-
- The DRIVE DATA GRAPH vertical axis is normally scaled in capacity (Kb/Mb). The
- scale is changed to percentage (%) when the data is sorted in any percentage
- order.
-
- By default, the DRIVE DATA SUMMARY and GRAPH are initially displayed in Drive
- Letter sort order. The current display order data is highlighted and is also
- shown on the bottom help line. There are also five other sort orders that they
- may be displayed in. The available display sort orders are:
-
- Drive Letter
- Capacity
- Utilization
- % Utilization
- Free
- % Free (reverse of % Utilization)
-
- -> To toggle the DRIVE DATA GRAPH and SUMMARY display sort order, press either
-
- 19
-
- MAIN DISPLAY INFORMATION DRIV_MAN Version 1.2
-
- the LEFTARROW or RIGHTARROW keys.
-
- DRIVE DATA SUMMARY
- ┌───────────────────────────────────────────────┐
- │ D Cap Utilized Free│D Cap Utilized Free │
- │ R Mb Mb/Kb % Mb/Kb│R Mb Mb/Kb % Mb/Kb │
- │ ░░░░░░░░░░░░░░░░░░░░░░│░░░░░░░░░░░░░░░░░░░░░░ │
- │ ░░░░░░░░░░░░░░░░░░░░░░│O__35__32.1m_92___2.9m │
- │ C 33 16.2m 48 17.2m│P__70__60.7m_87___9.2m │
- │ D 67 42.3m 63 24.5m│Q__70__43.8m_63__26.1m │
- │ E 67 28.1m 42 38.8m│R__70__33.4m_48__36.5m │
- │ F 67 37.1m 55 29.7m│S__70__56.3m_81__13.6m │
- │ G 67 26.7m 40 40.1m│T__70__48.4m_69__21.5m │
- │ H 67 52.7m 79 14.1m│U__70__33.3m_48__36.6m │
- │ I 67 39.5m 59 27.3m│V__70__32.8m_47__37.1m │
- │ J 67 57.2m 86 9.6m│W__35__34.0m_97_970.8k │
- │ K 80 38.6m 48 41.6m│X__11___7.2m_64___4.1m │
- │ L 19 12.2m 64 6.8m│Y__15__10.8m_73___3.9m │
- │ M...1...0.0k..0.520.2k│Z_130__51.3m_39__79.1m │
- └───────────────────────────────────────────────┘
-
- Drive data for each selected and available logical disk drive is shown in
- two groups: A-M on the left and N-Z on the right, in Drive Letter Order.
-
- The data columns displayed are:
-
- Logical disk DRive letter.
- Drive Capacity, rounded to the nearest Megabyte.
- Drive Used Storage, Kilobytes(k) or Megabytes(m), rounded to the nearest
- tenth.
- Drive Used Storage, rounded to the nearest Percent(%).
- Drive Free Storage, Kilobytes(k) or Megabytes(m), rounded to the nearest
- tenth.
-
- The information for each logical drive is normally separated by spaces for disk
- devices, either hard of floppy. A separator of periods, '.', is used for ram
- disk devices and a separator of an underscore, '_', for network devices.
-
- See the previous section, "DRIVE DATA GRAPH", for information on the sort order
- of the DRIVE DATA SUMMARY.
-
- TOTAL DISK SUMMARY
- ┌───────────────────────────────────────────────┐
- │ ┌Total Bytes CAPACITY = 1,316,579,328───────┐ │
- │ │Total Bytes UTILIZED = 794,632,192 (60%) │ │
- │ └────Total Bytes FREE = 521,947,136 (40%)───┘ │
- └───────────────────────────────────────────────┘
-
- The TOTAL DISK SUMMARY is self-explanatory. Total Bytes UTILIZED is calculated
- as Total Bytes CAPACITY minus Total Bytes FREE.
-
- TOTAL DISK data includes only those drives that were selected - the default is
- all drives to display and use.
-
- 20
-
- DRIV_MAN Version 1.2 MAIN DISPLAY INFORMATION
-
- TOTAL DISK GRAPH
- ┌───────────────────────────────────────────────┐
- │ ┌0% 10 20 30 40 50 60 70 80 90 100┐ │
- │ └▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▄▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀▀┘ │
- └───────────────────────────────────────────────┘
-
- The TOTAL DISK GRAPH shows two bars: the first, from 0%, is the percent UTILIZED
- and the second, to 100%, is percent FREE.
-
- INDIVIDUAL DRIVE DATA
- ┌───────────────────────────────────────────────────────────────────────────┐
- │ ╒╡ DRIVE C ╞═════╡ CAPACITY ╞═════╡ UTILIZED ( 48.4%) ╞╡ FREE ( 51.6%) ╞╕ │
- │ ╘╡ UTILITY-4C ╞╡ 33,431,552 ╞╡ 16,183,296 ╞════╡ 17,248,256 ╞╛ │
- └───────────────────────────────────────────────────────────────────────────┘
-
- The INDIVIDUAL DRIVE DATA section is displayed at the lower portion of the
- screen and may be scrolled, either by pressing the desired DRIVE LETTER or using
- the applicable cursor arrow keys. Its four portions are detailed below:
-
- Logical DISK DRIVE whose data is displayed and its Volume Label.
-
- Selected logical drive CAPACITY in bytes.
-
- Selected logical drive USED STORAGE in bytes and percentage.
-
- Selected logical drive FREE STORAGE in bytes and percentage.
-
- -> To display another DRIVE's full data, press the desired DRIVE letter or used
- the cursor arrow keys - HOME END UPARROW DOWNARROW PAGEUP
- PAGEDOWN .
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 21
-
- MAIN DISPLAY INFORMATION DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 22
-
-
- EDITING THE DISK DRIVE RANGE
-
- The selected disk DRIVE RANGE may be changed and re-displayed without exiting
- and re-running DRIV_MAN. Especially useful in a network environment, the range
- can be set for the physical drives of each system.
-
- -> To change the selected/displayed DRIVE RANGE, press F2 . The currently se-
- lected DRIVE RANGE is displayed. Edit the DRIVE RANGE, using the control keys
- noted on the bottom help line, as it would have been entered on the command
- line. For examples of range entries and the logical drives displayed, see the
- section "Command line FIRST-LAST DRIVE examples".
- ┌────────────────────────────────────────┐
- │ ╔═╡ Edit the selected DRIVE RANGE ╞═╗ │
- │ ║ ║█ │
- │ ║ C-M ║█ │
- │ ║ ║█ │
- │ ║ If floppy drive(s) are included ║█ │
- │ ║ in the range, there must be ║█ │
- │ ║ diskettes in those drive(s). ║█ │
- │ ╚═══════════════════════════════════╝█ │
- │ █████████████████████████████████████ │
- └────────────────────────────────────────┘
-
- -> To accept the DRIVE RANGE as edited, press ENTER .
-
- -> To leave the DRIVE RANGE as it was before editing, press ESCAPE .
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 23
-
- EDITING THE DISK DRIVE RANGE DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 24
-
-
- STORING THE DISPLAY DATA
-
- The DRIV_MAN screen display, of the Disk Summary Data, may be saved to disk to
- allow comparisons with previous or future displays.
-
- Using this feature, a snapshot of the current disk status may be saved before
- cleaning up a logical drive/drives and then another snapshot saved afterward,
- for comparison. Another use is to take Disk Summary snapshots daily, weekly, or
- monthly to see how the system's disk status is changing over time.
-
- -> To store the current Disk Summary Data screen display, press F3 . The screen
- display, except for the bottom help line, will be stored in a file named
- "DRIVE_MAN.DAT", and a completion message displayed. If this file already
- exists, on the drive-directory on which the program is located, the current
- data will be APPENDED to it. If the file does not exist, it will be CREATED
- on the same drive-directory as the program.
- ┌───────────────────────────────────────────┐
- │ ┌─┤ MESSAGE ├──────────────────────────┐ │
- │ │ Screen data appended to DRIV_MAN.DAT │█ │
- │ └──────────────────────────────────────┘█ │
- │ ████████████████████████████████████████ │
- └───────────────────────────────────────────┘
-
- -> To continue with program execution, press any key.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 25
-
- STORING THE DISPLAY DATA DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 26
-
-
- RUNNING A FILE MANAGER
-
- DRIV_MAN has the capability of "shelling" out to DOS and running another pro-
- gram. This is to allow a file manager to be run in conjunction with DRIV_MAN.
-
- FILE_MAN, another shareware program from MicroMetric, is a menu driven file
- manager utility. It, or another file manager, may be run directly from DRIV_MAN
- to copy, move, delete files or perform other file maintenance functions.
-
- -> To run FILE_MAN, first select the desired drive by pressing it's letter, and
- then press F4 .
- If the file manager program requested is present, DRIV_MAN first changes the
- current drive to that displayed in the INDIVIDUAL DRIVE DATA section, and
- then loads the file manager. Upon its completion, control is returned to
- DRIV_MAN.
- If the file manager program requested is not present, a message such as that
- shown below is displayed.
- ┌───────────────────────────────┐
- │ ┌─┤ MESSAGE ├──────────────┐ │
- │ │ FILE_MAN.COM not present │█ │
- │ └──────────────────────────┘█ │
- │ ████████████████████████████ │
- └───────────────────────────────┘
-
- NOTE Registered users may change the name of the desired file manager by use
- of the configuration file. See the next chapter for detailed informa-
- tion.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 27
-
- RUNNING A FILE MANAGER DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 28
-
-
- EXTENDED FILE INFORMATION
-
- The normal drive information is obtained through the DOS software interrupt 21H,
- Function 36H, "Get Drive Allocation Information". Additional information may
- also be obtained from Function 44H, Subfunction 0DH, Minor Subfunction 60H,
- "IOCTL: Generic I/O Control for Block Devices, Get Device Parameters". Only a
- limited set of this information can and is presented on the SINGLE SCREEN infor-
- mation. However, all of the data can be displayed, one drive at a time, if de-
- sired.
-
- -> To display EXTENDED FILE INFORMATION for all displayed drives, press F10 .
- EXTENDED FILE INFORMATION for the first drive will be shown, as seen below.
- The first six pieces of data are obtained with the "Get Drive Allocation"
- interrupt.
-
- NOTE For Novell networks, a problem exists in that drives may be format-
- ted with more than 65,536 clusters/drive. To date, we have not been
- able to find a DOS function that will determine the correct number
- of clusters per drive. Therefore, for these drives, the reported
- capacity will be incorrect. This problem does not occur with drives
- partitioned with the DOS program FDISK.
-
- The last two, denoted by stars, '*', are from the "IOCTL" interrupt.
-
- NOTE The starred Sectors/drive and the calculated Capacity normally in-
- clude disk space not available and marked as "bad sectors".
-
- Drive block devices that are non-disk, such as "RAM DRIVES", are
- so marked.
-
- Network drives, that are not accessible by the "IOCTL" interrupt,
- are also so marked.
- ┌───────────────────────────────────────┐
- │ ╒═╡ Drive C Extended Information ╞═╕ │
- │ │ Sectors/cluster 4 │█ │
- │ │ Avail. clusters 8,149 │█ │
- │ │ Bytes/sector 512 │█ │
- │ │ Cluster/drive 16,324 │█ │
- │ │ Capacity 33,431,552 │█ │
- │ │ Free 16,689,152 │█ │
- │ │ Sectors/drive* 65,457 │█ │
- │ │ Capacity* 33,513,984 │█ │
- │ ╘══════════════════════════════════╛█ │
- │ ████████████████████████████████████ │
- └───────────────────────────────────────┘
-
- -> To display the next drive's EXTENDED FILE INFORMATION, press ENTER .
- -> To cancel the display of EXTENDED FILE INFORMATION and return to the Main
- Display, press ESCAPE .
-
-
-
-
-
-
- 29
-
- EXTENDED FILE INFORMATION DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 30
-
-
- SHAREWARE REGISTRATION REMINDER SCREEN
-
- If your copy of DRIV_MAN is unregistered, a shareware registration reminder
- screen is displayed at the program exit. After a short graphics display, the
- available action keys are displayed on the bottom line.
-
- ╒═╡ DRIVe_MANagement Disk (C-Z) Summary ╞══════════════════╡ 12/31/99 01:00 ╞═╕
- │ >DRIV_MAN is being distributed as SHAREWARE, a concept that allows users to │
- │ examine a program on a trial basis at minimal charge before purchasing it. │
- │ >In addition, by decreasing marketing costs, professional quality software │
- │ is distributed at a fraction of the comparable commercial product cost. │
- │ >Regardless of whether you register the program, please help distribute it │
- │ by sharing unmodified copies of its files with others. You are granted the │
- │ right to use the DRIV_MAN program for a *thirty* day evaluation period. │
- │ ┌───────┐ >If you continue to use the program after this test period, │
- │ ┌────┴──┐ │ YOU MUST REGISTER ITS USE, which will provide you with: │
- │ │A ┌────┴──┐ │ * A 7" x 8 1/2" printed/bound DRIV_MAN manual. │
- │ │S │ Member│ │ * Latest version of the program on diskette. │
- │ │P │ o ├─┘ * Notification of the next DRIV_MAN release. │
- │ └──┤ ║ │ * Ability to suppress this display, use configuration file │
- │ └───────┘ ADDRESS: MicroMetric Program Registration.....$25. │
- │ Tech. Support(813)377-2515 98 Dade Avenue Latest Diskette only.....$10. │
- │ Order line...(800)929-0184 Sarasota FL 34232-1609 USA │
- │ ███████ ████████ ██ ██ ██ ██ ██ ██ ██ ██ │
- │ Ç────┬────────────────────────────────────┐ ███ ███ ████ ███ ██ │
- │ ┌┼┐██ │ Thank you for evaluating DRIV_MAN! │█ ███ ███ ██ ██ ██ ██ ██ │
- │ ┌┴┐██ └────────────────────────────────────┘ ██ ██ ██ ██████ ██ ███ │
- │ ═┴═┴═██████ ██ ██ ██ ██ ██ ██ ██ ██ ██ ██ ██ │
- │ │
- ╘╡ DRIV_MAN Version 1.20, Copyright 1992-94 MicroMetric, All Rights Reserved ╞╛
- F1>Help│F3>Print Order Form│F4>Brand System│ANY OTHER KEY>Exit│
-
- -> To print a shareware registration order form, make certain you printer is
- ready and then press F3 .
- -> If you have registered DRIV_MAN and received your registration number, press
- F4 . For detailed instructions on entering the registration information, see
- the section "INSTALLING THE SYSTEM, REGISTERED VERSION", step 8.
- -> To return to DOS, press any other key. The program will also return to DOS
- after ten seconds if no key is pressed.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 31
-
- SHAREWARE REGISTRATION REMINDER SCREEN DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 32
-
-
- USING A CONFIGURATION FILE
-
- NOTE USE OF THE CONFIGURATION FILE IS LIMITED TO REGISTERED USERS.
-
- The optional DRIV_MAN configuration file contains all of the display color and
- position variables. These variables are initially set to the program defaults.
- They may be edited by use of any ASCII editor/word processor.
-
- All DRIV_MAN CONFIGURATION FILES are ASCII files and have the name "DRIV_MAN".
- The default CONFIGURATION FILE has an extension of ".CFG". It may be edited by
- any word processor, using the word processor's option for editing and saving
- unformatted files.
-
- Additional CONFIGURATION files may be created and used by DRIV_MAN. For the
- procedure of using a CONFIGURATION FILE with an extension other than ".CFG",
- see the chapter "RUNNING DRIV_MAN".
-
- -> To change a default value in the CONFIGURATION FILE, edit the parameter as
- desired. Any ASCII character may be used in a parameter string EXCEPT for
- carriage return (13). All characters are entered using their ASCII codes.
- (Hold the ALTERNATE key down and enter the ASCII code using the numeric
- keypad only.) To comment out a parameter, add a '*' at the beginning of its
- line.
-
- NOTE The format of the DRIV_MAN parameters is:
-
- [parameter #]:{description}{max. length}=[value]
-
- Care should be taken in relocating the various display sections. There are three
- types of location changes that can be made:
-
- 1. INDIVIDUAL DRIVE DATA on the top of the display, rather than on the bot-
- tom.
-
- 2. DRIVE DATA GRAPH on the right of the display, rather than on the left.
-
- 3. DRIVE DATA SUMMARY, TOTAL DISK SUMMARY, and TOTAL DISK GRAPH may be rear-
- ranged within their display space.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 33
-
- USING THE CONFIGURATION FILE DRIV_MAN Version 1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 34
-
-
- DRIV_MAN FILES
-
- DRIV_MAN is normally distributed as compressed archives consisting of the fol-
- lowing files (these files are included in the compressed file DMANvvv, where vvv
- is the version):
-
- Files required for DRIV_MAN operation:
-
- DRIV_MAN.EXE . . Executable program
- DRIV_MAN.CFG . . Program configuration file
-
- Additional files necessary for FULL DRIV_MAN operation:
-
- DRIV_MAN.HLP . . Help text information
- DRIV_MAN.ORD . . Shareware/retail registration order form
-
- Files included to aid in the use of DRIV_MAN:
-
- DRIV_MAN.DOC . . DRIV_MAN documentation manual
- DRIV_MAN.ICO . . DRIV_MAN Windows icon
- DRIV_MAN.PIF . . DRIV_MAN Windows program information file
-
- Additional files in the distribution archive:
-
- DESC.SDI . . . . BBS program description
- FILE_ID.DIZ . . . BBS program description
- README.DM . . . . Text file consisting of program summary, features, and history
- SYSOP.DOC . . . . SYSOP distribution information
- VENDOR.DOC . . . Diskette/CD ROM vendor distribution information
- DRIV_MAN.LST . . List of DRIV_MAN files in the distribution file
-
- The registered version diskette includes these additional files:
-
- Installation files:
-
- INSTALL.EXE . . . Installation program
- INSTALL.HLP . . . Installation program help file
- INSTALLZ.EXE . . Installation unpack program
- INST_SYS.ZIP . . Installation program files
- README . . . . . Installation read me file
-
- The files that can be generated or used by DRIV_MAN consist of:
-
- DRIV_MAN.DAT . . DRIV_MAN screen data file.
- DRIV_MAN.REG . . DRIV_MAN registration information.
-
-
-
-
-
-
-
-
-
-
- 35
-
- DRIV_MAN FILES DRIV_MAN Version 1.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 36
-
-
- INDEX
-
- Action steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1, 13
-
- Brackets and parentheses . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Brand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 9, 10, 31
-
- Cancel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7, 10, 29
- Command line first-last drive examples . . . . . . . . . . . . . . . . . 13, 23
- Command line parameters . . . . . . . . . . . . . . . . . . . . . . . . . 13, 16
- Computer key conventions . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Configuration file . . . . . . . . . . . . . . 1, 3, 13, 16, 18, 27, 31, 33, 35
-
- DRIV_MAN files . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 10, 35
- Drive data graph . . . . . . . . . . . . . . . . . . . . . . . . . 1, 18-20, 33
- Drive data summary . . . . . . . . . . . . . . . . . . . . . . 1, 15, 18-20, 33
- Drive range . . . . . . . . . . . . . . . . . . . . . . . . . . . 1, 16, 18, 23
- Drive-directory path . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
-
- Editing the disk drive range . . . . . . . . . . . . . . . . . . . . . . 16, 23
- Extended file information . . . . . . . . . . . . . . . . . . . . . . . . 16, 29
-
- File manager . . . . . . . . . . . . . . . . . . . . . . . . . 1, 8, 15, 16, 27
- From a BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
- From a diskette vendor . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
-
- General display information . . . . . . . . . . . . . . . . . . . . . . . . . 18
-
- Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2, 18
- Help key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3, 6, 15, 16
-
- Individual drive data . . . . . . . . . . . . . . . . . . 1, 15, 18, 21, 27, 33
- Installing the system . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 31
- Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1, 16
-
- Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3, 33
-
- Main display action keys . . . . . . . . . . . . . . . . . . . . . . . . . . 15
- Main display information . . . . . . . . . . . . . . . . . . . . . . . . . . 17
- Major features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
- Manual format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1, 6, 13
- Monochrome monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
-
- Network . . . . . . . . . . . . . . . . . . . . . . . . . . . ii, 17, 20, 23, 29
- Novell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
-
- Operation keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
-
- Page layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Program operation with Microsoft Windows . . . . . . . . . . . . . . . . . . 11
-
- Registered version . . . . . . . . . . . . . . . . . . . . . . . . . 5, 31, 35
-
- 37
-
- INDEX DRIV_MAN Version 1.2
-
- Running a file manager . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
- Running DRIV_MAN . . . . . . . . . . . . . . . . . . . . . . . 5, 6, 13, 23, 33
-
- Shareware . . . . . . . . . . . . . . . . . . . . . . ii, 1-3, 5, 16, 27, 31, 35
- Shareware distributed documentation manual . . . . . . . . . . . . . . . . . 2
- Shareware registration reminder screen . . . . . . . . . . . . . . . . . . . 31
- Sort order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1, 19, 20
- Storing the display data . . . . . . . . . . . . . . . . . . . . . . . . . . 25
- Support BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii, 3
- System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
-
- Technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii, 3
- Total disk graph . . . . . . . . . . . . . . . . . . . . . . . . 1, 18, 21, 33
- Total disk summary . . . . . . . . . . . . . . . . . . . . . . . 1, 18, 20, 33
-
- Using a configuration file . . . . . . . . . . . . . . . . . . . . . . . 1, 33
-
- ■■■■_MAN programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- 38
-